Welcome to
 
GLOBAL BULK CONTAINERS
Home | Company Profile | Contact Us | News

SOLUTION
Why IBC «  
Commodity «  
Test Report «  
Comparison «  
 
Cost Savings «  
Storage Efficiency «  
Health, Safety «  
& Environment     

:: TEST REPORT ::

Product Name/Model Testing Type/Testing Criteria Date of Commission/Date of Test
Foldable IBC/ Cube 1000 Commission/ ISATA 7C 13 May 2008/ 15 May 2008
Cubage Sample Dimensions Total Sample
1000 liters 1140mm*1140mm*1085mm 5 IBC
Sample Status
Folded Metal Intermediate Bulk Container (ton case). There is a plastic woven bag in the case. Inside the woven bag, there is a PE inner bag to hold the bobweight water. The case and plastic woven bag and PE inner bag are normal
Test Items
Compression-empty container machine compression, Compression-filled container machine compression, Compression-machine compression, Random vibration, Rotational flat drop test, Rotational corner flat drop test, Impact test


Sample A Compression empty container machine compression

Sample B Compression Filled container machine compression

Center an empty container on compression tester. 2 Start the test machine and bring the platens together at the rate of 0.5in per minute until 9000kg.

Result:
The sample is not damaged.



Sample: C & D Compression machine compression

Sample E Random Vibration

Center two containers on compression tester. Start the test machine and bring the platens together at the rate of 0.5in per minute until 2000kg.

Result:
The sample is not damaged.

  • Place a filled container on the vibration table so that face 3 rests on the platform.
  • Time: 180 minutes.
  • Grms level: 0.54
Sample A: Rotational flat drop test
  • Place filled container onto a flat, rigid surface.
  • Falls freely edge 3-5 & 3-6 onto a flat, rigid surface.
  • The height of dropping is 6 in.

Result:
The sample is not damaged.

Sample B: Rotational corner flat drop test
  • Place sample onto a flat, rigid surface.
  • Falls freely corner 2-3-5 & 3-4-6 onto a flat, rigid surface.
  • The height of dropping is 6 in.

Result:
The sample is not damaged.

Sequence Orientation Specific Face
1 Face 5
2 Face 6
3 Face 2
4 Face 4
Equipment Manufactory Model Date of Calibration Calibration Cycle Incline Impact
Testing Machine Self Made XCH-01 2007.05.28 1 year
Vibration System USA LANSMONT 1800-5 2007.09.03 1 year
Dynamic Compressive Machine France SEREME 100kN 2007.09.03 1 year
Shedding lifting hook drop tester France SEREME 1500kg 2007.05.28 1 year